← All projects
Social Impact 01 · Medical AI

Temporal Consistency and Uncertainty-aware Segmentation for Cardiovascular Ultrasound Videos

Build an automatic segmentation framework for cardiovascular ultrasound images and videos, improving single-frame accuracy, cross-frame stability, weak-label robustness, and the reliability of EF / EDV / ESV estimation.

Input: ultrasound image / video sequenceMiddle: temporal alignment / uncertainty mapOutput: stable masks + clinical metrics
Cardiovascular ultrasound segmentation teaser

Medical image segmentation should not only make a single-frame mask look accurate; it should be stable over time and reliable enough to support metric estimation.

Research Framing

Medical AI through stability and reliability

This direction examines how deep learning methods connect with real health-related problems. It offers clear visual results and a strong social-impact story through clinical metrics and generalization tests.

Research question

Why does high single-frame Dice not guarantee reliable ultrasound video analysis?

Analyze how speckle noise, blurred boundaries, and fast cardiac motion create mask jitter that affects volume and EF estimation.

Contribution

Temporal consistency + uncertainty-aware learning

Design cross-frame alignment, uncertainty-based pseudo-label filtering, and clinical consistency constraints, then validate each module through ablations.

Possible outputs

Research artifacts

Baseline reproduction, video segmentation demo, uncertainty maps, temporal smoothness curves, cross-dataset tests, and a conference-style paper.

Input / Output

Inputs, intermediate results, and final artifacts

The project starts from public ultrasound datasets and outputs segmentation, stability analysis, and clinical-metric evaluation.

01
Input data

CAMUS, EchoNet-Dynamic, HMC-QU, and related ultrasound image or video datasets.

02
Temporal modeling

ConvLSTM, Temporal Transformer, cross-frame attention, or optical-flow alignment.

03
Reliability constraints

Segmentation masks plus pixel-level uncertainty for pseudo-label filtering and boundary diagnosis.

04
Final results

LV, myocardium, and LA masks, temporal smoothness metrics, EF / EDV / ESV errors, and demo visualizations.

Research Position

Core problem

Many segmentation models process each frame independently, but cardiac structures move continuously through the cardiac cycle.

This project shifts the goal from “is the mask accurate?” to “is the mask stable, trustworthy, and useful for metric computation?”

Social Impact

Possible outputs

Possible outputs include a runnable system, visual results, clinically relevant evaluation, and a conference-style paper.

ultrasound video segmentation demouncertainty heatmaptemporal smoothness curvesEF / EDV / ESV error tablecross-dataset analysisshort / full paper
Research Path

Research path

Progress is organized by research maturity and concrete intermediate artifacts.

Stage ATask and data

Understand ultrasound views, LV / myocardium / LA labels, EF / EDV / ESV, and data splits.

Stage BSegmentation baseline

Reproduce U-Net, DeepLabV3+, TransUNet, or Swin-UNet.

Stage CTemporal consistency

Add ConvLSTM, cross-frame attention, or temporal loss to reduce mask jitter.

Stage DUncertainty and metric constraints

Use uncertainty maps, pseudo-label filtering, and EF / volume consistency constraints.

Stage EPaper experiments

Complete comparisons, ablations, cross-dataset tests, metric analysis, and failure cases.

Research Details

Core technical components

The method focuses on video modeling, uncertainty estimation, and clinical consistency.

Temporal Feature Fusion

Align or attend across neighboring frames so the model understands continuous cardiac motion.

Uncertainty-aware Decoder

Predict both masks and uncertainty to identify low-confidence boundaries and weak pseudo-labels.

Clinical Consistency

Connect segmentation outputs with EF, EDV, ESV, or cardiac phase constraints.

Evaluation

Evaluation

Evaluation should explain whether the model is accurate, stable, and useful for downstream metrics.

Metric / ObservationTechnical meaningIntuitive explanation
Dice / IoUOverlap between predicted and reference masks.Does the model segment the target structures correctly?
HD95 / ASSDBoundary and surface-distance errors.Are the chamber and myocardium boundaries aligned?
Temporal SmoothnessStability of mask area, boundary, or shape across frames.Does the video segmentation jitter when played over time?
EF MAE / RMSEError of ejection fraction estimated from masks.Does better segmentation improve cardiac-function estimation?
Uncertainty CalibrationAgreement between low confidence and real errors.Does the model know where it is uncertain?
Cross-dataset PerformanceGeneralization across devices, views, or datasets.Can the method transfer beyond one benchmark?
Datasets & References

Public datasets and reference directions

These datasets support segmentation, video modeling, and external validation.

CAMUS dataset reference
CAMUS

2D cardiac ultrasound images for LV, myocardium, and LA segmentation. Dataset page

EchoNet-Dynamic dataset reference
EchoNet-Dynamic

Large-scale ultrasound videos for video modeling and EF estimation. Dataset page

HMC-QU dataset reference
HMC-QU

Ultrasound records for external validation and cross-dataset testing. Dataset page

Generated images are used to keep visual style consistent; dataset use should follow each dataset's license and terms.